Goulds 3196 replacement pumps come from three sources: ITT Goulds itself (the 3196 i-FRAME), non-OEM manufacturers whose own pages describe a pump built to the 3196 dimensional pattern (Dynapro D-196, Sunbo G series, Curflo G-Line and YSM G196), and repair of the installed pump with OEM or non-OEM parts of the same size and frame. Under ASME B73.1 a pump of the same designation and frame group is built to the same mounting, nozzle, shaft and baseplate envelope; the standard does not fix hydraulics, seal-chamber geometry beyond the minimum envelope, materials or internal parts. Interchange for any of them is confirmed against the installed pump’s nameplate and drawing before order.
Goulds, 3196 and i-FRAME are trademarks of ITT Inc. YSM Pumps (Jinan Yingsiman Machinery Co., Ltd.) is an independent non-OEM manufacturer and is not affiliated with, sponsored by, endorsed by or a distributor for ITT Goulds or any other manufacturer named on this page. OEM model names are used only to identify the dimensional pattern.
Three routes to replace a Goulds 3196
No route is ranked here.
- Route A, a new OEM pump. The ITT Goulds 3196 i-FRAME product page states 29 sizes on 5 power ends (STi, MTi, LTi, XLTi, i17). OEM literature states that the 3196 meets ANSI/ASME B73.1M, that pressure-retaining components are hydrostatically tested and that i-FRAME pumps carry a 5-year warranty (gouldspumps.com 3196 i-FRAME page, OEM brochure and IOM).
- Route B, a new non-OEM pump built to the 3196 dimensional pattern. Pattern means the same ASME B73.1 designation, frame group and foot, nozzle and shaft envelope, not the same castings, curves, seal chambers or bought-out components. Makers whose own pages describe a 3196-pattern line are Dynapro D-196, Sunbo G series, Curflo G-Line and YSM G196; for any of them, interchange with a specific installed pump is confirmed against the nameplate and the installed pump drawing before order. Other manufacturers’ ANSI process pumps are covered in the supplier section, listed with what their own pages and literature publish.
- Route C, repair the installed pump. Keep the power end if it is sound and renew the wet end or individual parts. With OEM parts through authorised distribution, the OEM’s warranty terms apply as the OEM publishes them, and part identity is confirmed against the nameplate and serial number (the Goulds IOM asks for serial number, model and size when ordering). With non-OEM parts built to the same dimensional pattern, size and frame, the buyer checks the OEM warranty terms first, and interchange is confirmed against the nameplate and the installed pump drawing before order.
The drivers are qualitative: condition of power end against wet end; traceability of nameplate and part numbers; documentation demanded; like-for-like material or upgrade; fleet spares harmonisation; witness-test requirements; delivery scope. See repair or replace an industrial process pump, how to compare process pumps from multiple manufacturers and pump efficiency and cost of ownership.
What ASME B73.1 fixes, and what it leaves to the manufacturer
The standard’s interchangeability rule covers pumps of the same standard dimension designation: they share mounting dimensions, the size and location of the suction and discharge nozzles, the input shaft, the baseplate and the foundation bolt holes (ASME B73.1 scope, asme.org). For a specific installed pump, interchange is confirmed against the nameplate and the installed pump drawing before order.
In practice the standard covers the D, CP and X dimensions, the foot bolt pattern, flange sizes and positions, shaft extension and keyway, back pull-out construction and a minimum seal-chamber envelope. Lettered dimensions are not reproduced on this page. The letters are tabulated by designation on G196 vs Goulds 3196 interchangeability, the lettered drawing is on technical downloads, and the certified drawing issued with the quotation governs.
The standard does not fix head, efficiency or NPSHr; impeller and casing castings; seal-chamber geometry beyond the minimum (enlarged-bore and tapered-bore chambers are manufacturer designs); power-end internals; or materials. Two pumps can share the same B73.1 envelope yet deliver different curves. ISO 2858 and ISO 5199 pumps use a different envelope; their parts are not interchangeable with B73.1 pumps.
Size strings need care: Goulds writes discharge x suction, then nominal impeller diameter (2x3-13), while some other OEM patterns write suction x discharge (3x2-13) for the same A30 designation. Compare designations, not strings, and verify the designation with the supplier or by measurement, since some makers offer larger nominal impellers on the same envelope (see ANSI/ASME B73.1 explained). Every row below is confirmed against the nameplate and the installed pump drawing before order.
| B73.1 designation | Goulds 3196 sizes (discharge x suction, nominal impeller diameter; in) | Goulds frame (legacy name) | Goulds i-FRAME power end | G196 general-purpose coverage (ysmpumps.com) |
|---|---|---|---|---|
| AA | 1x1.5-6, 1x1.5-8 | STX | STi | 1x1.5-6, 1x1.5-8, confirm against the nameplate and installed pump drawing |
| AB | 1.5x3-6, 1.5x3-8 | STX | STi | 1.5x3-6, 1.5x3-8, confirm against the nameplate and installed pump drawing |
| AC | 2x3-6 | STX | STi | 2x3-6, confirm against the nameplate and installed pump drawing |
| A05 | 1x2-10 | MTX/LTX | MTi/LTi | 1x2-10, confirm against the nameplate and installed pump drawing |
| A50 | 1.5x3-10 | MTX/LTX | MTi/LTi | 1.5x3-10, confirm against the nameplate and installed pump drawing |
| A60 | 2x3-8, 2x3-10 | MTX/LTX | MTi/LTi | 2x3-8, 2x3-10, confirm against the nameplate and installed pump drawing |
| A70 | 3x4-7, 3x4-8, 3x4-8G, 3x4-10 | MTX/LTX | MTi/LTi | 3x4-8, 3x4-8G, 3x4-10, confirm against the nameplate and installed pump drawing; 3x4-7 available on request, confirm against the nameplate and installed pump drawing |
| A20 | 1.5x3-13 | MTX/LTX | MTi/LTi | 1.5x3-13, confirm against the nameplate and installed pump drawing |
| A30 | 2x3-13 | MTX/LTX | MTi/LTi | 2x3-13, confirm against the nameplate and installed pump drawing |
| A40 | 3x4-10H, 3x4-13 | MTX/LTX | MTi/LTi | 3x4-10H, 3x4-13, confirm against the nameplate and installed pump drawing |
| A80 | 4x6-10G, 4x6-10H, 4x6-13 | MTX/LTX | MTi/LTi | 4x6-10 (OEM lists 4x6-10G; confirm against the nameplate and installed pump drawing), 4x6-10H, 4x6-13, confirm against the nameplate and installed pump drawing |
| A90 | 6x8-13 | XLTX | XLTi | 6x8-13, confirm against the nameplate and installed pump drawing |
| A100 | 8x10-13 | XLTX | XLTi | 8x10-13, confirm against the nameplate and installed pump drawing |
| A105 | 4x6-17 (i17) | XLTX | i17 | 4x6-17 available on request, confirm against the nameplate and installed pump drawing |
| A110 | 6x8-15, 6x8-15N, 6x8-17 (i17) | XLTX | XLTi; i17 for 6x8-17 | 6x8-15, confirm against the nameplate and installed pump drawing; 6x8-15N available on request, confirm against the nameplate and installed pump drawing; 6x8-17 available on request, confirm against the nameplate and installed pump drawing |
| A120 | 8x10-15, 8x10-15G, 8x10-16H (i17), 8x10-17 (i17) | XLTX | XLTi; i17 for 8x10-16H and 8x10-17 | 8x10-15, 8x10-15G, confirm against the nameplate and installed pump drawing; 8x10-16H available on request, confirm against the nameplate and installed pump drawing; 8x10-17 available on request, confirm against the nameplate and installed pump drawing |
- Designation, size and frame values: ITT Goulds Pumps, 3196 i-FRAME ANSI Process Pump brochure B.3196.en-US.2026-03 (p.17 Construction Details, p.21 Dimensions). Size strings are as listed across the brochure’s construction and dimension pages; the OEM product page states 29 sizes; confirm the current size list with the OEM document. Sizes marked i17 use the OEM i17 power end. Lettered installation dimensions are not reproduced here; see G196 vs Goulds 3196 interchangeability and technical downloads. The certified drawing issued with the quotation governs.
- G196 column: G196 series (24 general-purpose sizes); Goulds 3196 sizes outside that list are available on request, confirm against the nameplate and installed pump drawing. G196 Low Flow sizes (1x1.5-8LF, 1x2-10LF, 1.5x3-13LF) are built to the Goulds LF 3196 dimensional pattern and are a separate pump, as are YSM’s self-priming pump and the G196 CV. This table covers general-purpose sizes only. Low-flow, self-priming and 17-inch sizes were developed after the original ASME B73.1 designation table was set, which is why the 1991 ASME B73.1M dimension table has no entries for them (the 17-inch sizes above are placed by designation from the ITT brochure); where no current OEM table gives a designation, installation dimensions come from the certified drawing. Same designation means the same mounting, nozzle and shaft envelope, not equal hydraulics, materials or internal parts; interchange is confirmed against the installed pump’s nameplate and drawing before order.
- Legacy STX/MTX/LTX/XLTX frame names are used on ysmpumps.com and in the aftermarket; current ITT literature uses STi/MTi/LTi/XLTi/i17.
Who makes Goulds 3196-pattern replacement pumps, and other ANSI process pumps for reference
Reading rule for the two tables below: “not published” means absent on the page or pages checked on 2026-09-10; it is not a judgement, not proof of absence site-wide, and never inferred from distributors, marketplaces, forums or search snippets. Three groups are tabulated: the OEM, ITT Goulds; non-OEM makers whose own pages describe a 3196-pattern line (Dynapro D-196, Sunbo G series, Curflo G-Line, YSM G196); and other manufacturers’ ANSI process pumps, listed with what their own pages publish: Summit 2196, PumpWorks PWA Gen2 and Peerless 8196. The Summit 2196 product page carries no Goulds interchange statement, and its brochure includes an interchangeability and dimensional data table; the PumpWorks and Peerless pages checked carry no Goulds 3196 interchange statement. Rebuilders and parts houses are out of scope and are not named.
| Supplier (product) | Interchange wording on own page (paraphrased) | Frames / sizes published | Wet-end materials published | Testing and inspection published | Source |
|---|---|---|---|---|---|
| ITT Goulds 3196 i-FRAME (OEM) | Reference design; OEM literature states the 3196 meets ANSI/ASME B73.1M | 5 power ends (STi, MTi, LTi, XLTi, i17); 29 sizes (OEM product page) | Ductile iron, 316SS, CD4MCu, Alloy 20, 317SS, Monel, Nickel, Hastelloy C, Hastelloy B, Titanium (IOM parts lists) | Hydrostatic testing of pressure-retaining components | [1] |
| Dynapro D-196 (Dynapro Pumps) | Publishes an interchange statement with the Goulds 3196 | not published | Ductile iron, 316SS, 316L, CD4MCu, Alloy 20, Hastelloy, Titanium | not published on the D-196 page | [2] |
| Sunbo Pump G series (Sunbo Pump) | Publishes an interchange statement with ITT Goulds 3196 | Sizes 1x1.5-6 to 8x10-15G listed; frame groups not published | CF8M, CD4MCu, higher alloys up to titanium | not published | [3] |
| Curflo G-Line (STX/MTX/LTX/XLTX) | Publishes an interchange statement with the Goulds 3196 and a CP/D/X/base dimension table by size; states OEM references are for identification only | STX, MTX, LTX, XLTX; dimension table by size | not published in the technical data sheet checked | not published | [4] |
| Summit Pump 2196 | No Goulds interchange statement on the product page; the brochure includes an interchangeability and dimensional data table | STO, MTO, LTO, XLO; sizes 1x1.5-6 to 8x10-15G (brochure) | not published on the product page | not published | [5] |
| PumpWorks PWA Gen2 | Sold as an ASME B73.1 process pump; Goulds interchange: not published on the official product page | not published on the official product page | Carbon-steel liquid ends; 316L shaft standard | not published | [6] |
| Peerless 8196 | No Goulds interchange statement on the page checked; B73.1 conformity not stated on the page checked | STP, MTP, XLTP frames | Casing: ductile iron, 316SS, CD4MCuN; power end cast iron (ductile iron on STP) | not published | [7] |
| YSM G196 (YSM Pumps, non-OEM) | Non-OEM, built to the Goulds 3196 dimensional pattern under ASME B73.1, same size and frame; confirmed against the nameplate and installed pump drawing before order | STX, MTX, LTX, XLTX; 24 general-purpose sizes (plus separate Low Flow, self-priming and CV pumps) | WCB, CF8M, CD4MCu, CN7M (Alloy 20), Monel, Nickel, Hastelloy B, Hastelloy C, Titanium, Zirconium alloy; availability by component and size confirmed at quotation | Material verification by spectrometer or chemical analysis per heat; hydrostatic test of pressure-containing parts; dimensional inspection of machined parts and ASME B73.1 interface dimensions against the drawing, with the in-house CMM (Tornado NCA10158) for interface and fit dimensions; dynamic balancing of all impellers; performance testing of complete pumps on YSM’s own factory test benches (water medium, to 9,000 m3/h, 6 bar, 250 kW), test curve supplied on request; final inspection | [8] |
- Peerless 8196 row: frames as published on Peerless’s own page (STP, MTP, XLTP). YSM cross-reference note, not a Peerless publication: YSM’s Peerless 8196 cross-reference page also covers LTP, the MTP variant corresponding to the Goulds LTX frame; fit is confirmed against the nameplate and the installed pump drawing before order.
All names in this table are trademarks of their respective owners; none of these companies has reviewed or endorsed this page, and YSM Pumps is not affiliated with any of them. Interchange for any row is confirmed against the installed pump’s nameplate and drawing before order.
| Supplier (product) | Warranty published | Third-party inspection / witness test | Manufacturing location published | Source |
|---|---|---|---|---|
| ITT Goulds 3196 i-FRAME (OEM) | 5-year warranty on i-FRAME ANSI process pumps | not published | not published | [1] |
| Dynapro D-196 (Dynapro Pumps) | not published | not published | not published | [2] |
| Sunbo Pump G series (Sunbo Pump) | not published | not published | not published (company address on page: Shijiazhuang, China) | [3] |
| Curflo G-Line (STX/MTX/LTX/XLTX) | not published | not published | not published | [4] |
| Summit Pump 2196 | not published | not published | not published (brochure carries a US address) | [5] |
| PumpWorks PWA Gen2 | not published | not published | not published on the product page (company address Houston, TX per pumpworks.com) | [6] |
| Peerless 8196 | 3-year warranty on all power ends | not published | not published | [7] |
| YSM G196 (YSM Pumps, non-OEM) | See published commercial terms | Witness testing and SGS, Bureau Veritas or TÜV third-party inspection available on request | Zhuangzhuang Industrial Park, Boshan District, Zibo, China (3,000 m2 site, operating since 2010) | [8] |
- gouldspumps.com/products/3196-i-frame; ITT Goulds 3196 i-FRAME brochure and IOM (public OEM documents). Checked 2026-09-10.
- dynaproco.com/interchangeable-goulds-3196-pump/ and a dynaproco.com technical-support article on Goulds replacements.
- sunbopump.com 3196 bare-pump page and 3196 parts (frames) page.
- curflo.com G-Line Series Technical Data 2021 (PDF); reseller pages not used.
- summitpump.com 2196 product page and 2196 brochure PDF; distributor statements not used.
- pumpworks.com PWA Gen2 product page; distributor brochures and blogs not used.
- peerlesspump.com/products/process/peerless-8196/.
- ysmpumps.com: G196 series, G196 ANSI chemical process pump and commercial terms; testing and inspection from certifications and quality only; factory review for the site location, 3,000 m2 area, 2010 start and staff figures only.
No price, cost or lead time is compared between rows; the warranty column restates each supplier’s own published wording. Goulds, 3196, i-FRAME, ITT, Dynapro, Sunbo, Curflo, Summit, PumpWorks, Peerless, Griswold and all other names are trademarks of their respective owners; YSM Pumps is an independent manufacturer and is not affiliated with, sponsored by or endorsed by any of them.
Competitor interchange statements are paraphrased, not quoted. Ask every supplier what is verified before order (nameplate, drawing, frame group); where a cell reads “not published”, ask rather than assume. No supplier is ranked or recommended; the checklist below is the comparison instrument. The G196 is also offered as a non-OEM replacement, same size and frame, confirmed against the nameplate and the installed pump drawing before order, as the G196 built to the Summit 2196 dimensional pattern, the G196 built to the Peerless 8196 dimensional pattern, the G196 built to the PumpWorks PWA Gen2 dimensional pattern and the G196 built to the Griswold 811 dimensional pattern.
Seven interchange checks before you order
The interface-by-interface reading of ASME B73.1 against the 3196 pattern, including which interfaces the standard fixes and which stay with the manufacturer, is set out on G196 vs Goulds 3196 interchangeability. This page keeps only the short form: seven checks that apply to any supplier, OEM or non-OEM, and verify a specific installed pump rather than a model name. The guides on reading a pump nameplate and drawing, what information is needed before replacing an ANSI process pump and the urgent parts RFQ checklist carry the detail.
Confirm before you order
- Nameplate: pump plate and motor plate photographed, never the motor plate alone; model, size, frame or group, serial number, material code and impeller diameter recorded.
- External interfaces: B73.1 designation, D, CP, X, base bolt pattern, nozzle size, rating and orientation, shaft extension and keyway, on the certified GA drawing issued with the quotation and checked against the installed pump drawing.
- Power end: frame group (never inferred from the size string), coupling hub bore against shaft diameter, sleeved or sleeveless shaft, isolator type and lubrication.
- Hydraulics: duty range, speed, liquid data, NPSHa against NPSHr and a curve for the offered trim; a performance test for duty-critical service.
- Seal: seal type, make, arrangement, chamber type and flush plan; an existing seal may not transfer (see mechanical seals for process pumps).
- Materials and documents: exact casting grade (ASTM designation) per part; GA drawing, sectional with parts list, curve, material certificates with heat numbers, dimensional inspection and test reports, matched on receipt to nameplate, serial and PO.
- Driver, coupling, base and rotation: rotation viewed from the coupling end; motor frame and position on the baseplate; coupling spacer length (DBSE); baseplate condition, foundation bolts and auxiliary connections.
Supplier comparison checklist: ten questions for every quotation
Send the same ten questions to every supplier and record “not published / not answered” where no answer comes; a marked gap is reviewable, a silent one is not. The YSM column reproduces published pages only. Answers that call for a follow-up, from any supplier: no frame group on the quotation; generic material names; no curve for the offered trim; no test scope; no written warranty term.
| Check | Ask every supplier for | Where to verify | YSM G196 published answer |
|---|---|---|---|
| 1. Dimensional envelope | B73.1 designation, D, CP, X, base bolt pattern, nozzle sizes and ratings, shaft diameter and keyway on a certified GA drawing | Installed pump nameplate and drawing + supplier certified GA drawing | Installation dimension sheets (CP, D, X, E1, E2, F, U, Y, H) and interchangeability tables (Rev. A, 2026-07) on technical downloads; dimensional inspection of machined parts and ASME B73.1 interface dimensions against the drawing, with the in-house CMM (Tornado NCA10158) for interface and fit dimensions; fit confirmed against the nameplate and installed pump drawing before order |
| 2. Frame / power end | Frame group, shaft diameter, bearing make, isolator type, sleeved or sleeveless shaft, lubrication | Nameplate + power-end sectional drawing | STX, MTX, LTX, XLTX; SKF or equivalent bearings; labyrinth bearing isolators; sleeved or sleeveless shaft arrangements; frames cast iron (ductile iron on STX), adapters ductile iron |
| 3. Wet-end materials | Exact casting grade (ASTM designation), heat number and material certificate, not “stainless” or “duplex” | MTR / spectrometer report | WCB, CF8M, CD4MCu, CN7M (Alloy 20), Monel, Nickel, Hastelloy B, Hastelloy C, Titanium, Zirconium alloy; availability by component and size confirmed at quotation; material verification by spectrometer or chemical analysis per heat; material certificates issued with the order |
| 4. Impeller and hydraulic check | Impeller type, diameter/trim, and a curve for the offered impeller; head, NPSHr and BEP position at the duty point | Supplier curve vs duty; witness performance test | Open impeller with external adjustment; coverage curves published; for re-patterned or reverse-engineered impellers the hydraulics are checked against the pump curve; performance testing as in check 6 |
| 5. Seal chamber options | Standard, enlarged-bore, tapered-bore or packed box; which seal makes and flush plans fit | Seal drawing vs chamber drawing | Standard, large-bore and taper-bore seal chambers; packed-box and mechanical-seal arrangements; John Crane or equivalent mechanical seals |
| 6. Testing | Hydrostatic test scope, dynamic balance report, performance test availability, witness option | Test certificates | Hydrostatic test of pressure-containing parts; dynamic balancing of all impellers; performance testing of complete pumps on YSM’s own factory test benches (water medium, to 9,000 m3/h, 6 bar, 250 kW), test curve supplied on request; final inspection; witness testing available on request |
| 7. Third-party inspection | Whether an independent inspection agency can be added to the order | Inspection agency report | SGS, Bureau Veritas or TÜV third-party inspection available on request |
| 8. Documentation | GA drawing, sectional with parts list, curve, MTRs, hydro / balance / dimensional inspection / test reports, IOM | Order document list | Sectional drawings with parts lists, coverage curves and installation dimensions on technical downloads; material certificates, balance reports and hydrostatic test reports issued with the order; a dimensional inspection report can be issued with the order; performance test curve supplied on request |
| 9. Warranty | Term, start date, exclusions | Written terms | See published commercial terms |
| 10. Lead time and commercial terms | Lead time by scope, payment terms, Incoterms, packing | Written terms | See published commercial terms; export packing in non-fumigation wooden export cases, with small parts in inner cartons |
YSM’s commercial terms are linked, not compared with any other supplier’s. SKF and John Crane are trademarks of their respective owners and are named only as bought-out component makes.
Complete pump, bare wet end or parts: matching scope to the problem
Complete pump. When the power end is worn, the duty has changed, or the plant wants a new nameplate and full documentation; confirm that the coupling, baseplate and motor frame remain (check 7).
Bare wet end on the existing frame. Casing, impeller, cover and adapter. Within the same G196 frame group, G196 power-end parts such as the bearing housing, shaft and isolators are typically shared across G196 sizes and pump types; casings, impellers and covers are specific to each pump type and size. The fit of a non-OEM wet end or part to an installed OEM frame is confirmed against the nameplate and the installed pump drawing before order.
Parts. OEM parts through authorised distribution (the IOM asks for serial number, model and size, and part identity is confirmed against the nameplate and serial number), or non-OEM parts built to the same dimensional pattern for the same size and frame group, confirmed against the nameplate and the installed pump drawing before order. YSM publishes YSM-reference to OEM part-number cross-reference tables for nine part groups, casing to feet, on replacement ANSI pump parts.
Obsolete, unmarked or damaged parts. These go through reverse engineering from a sample or drawing, using the digitising, casting and hydraulic-check capabilities described in the next section, so that re-patterned impellers are hydraulically checked against the pump curve rather than copied from worn geometry. Whatever the scope, B73.1 does not fix efficiency or NPSHr, so a curve for the offered trim belongs on the order for OEM and non-OEM parts alike.
How YSM builds and documents a G196 (published facts only)
YSM is an independent manufacturer. Pumps and parts are produced to YSM’s own drawings and patterns to the ASME B73.1 dimensional standard, are non-OEM, and are not supplied by or associated with ITT Goulds. Product details are on the G196 ANSI chemical process pump page.
YSM’s capabilities include 3D scanning or CMM digitising of cast surfaces and impeller vane profiles, casting simulation before pouring, and 3D-printed sand cores and moulds; re-patterned impellers are hydraulically checked against the pump curve.
The inspection steps published on certifications and quality are:
- material verification by spectrometer or chemical analysis per heat;
- hydrostatic test of pressure-containing parts;
- dimensional inspection of machined parts and ASME B73.1 interface dimensions against the drawing, with the in-house CMM (Tornado NCA10158) for interface and fit dimensions;
- dynamic balancing of all impellers;
- performance testing of complete pumps on YSM’s own factory test benches (water medium, to 9,000 m3/h, 6 bar, 250 kW), with the test curve supplied on request;
- final inspection.
Witness testing at the factory and SGS, Bureau Veritas or TÜV third-party inspection are available on request. Material certificates, balance reports and hydrostatic test reports are issued with the order; a dimensional inspection report can also be issued with the order. Export packing is non-fumigation wooden export cases, with small parts in inner cartons.
Sectional drawings, coverage curves and installation dimensions (Rev. A, 2026-07) are on technical downloads.
Manufacturing takes place on a 3,000 m2 site in Zhuangzhuang Industrial Park, Boshan District, Zibo, in operation since 2010 with about 35 staff (factory review).
Lead times, warranty, payment and Incoterms are published on how we work and are not restated here. Each quotation is prepared for a reviewed selection of size and frame, materials, sealing, scope and quantity rather than for a model name, so there is no public price list and no price is compared on this page. To start, request a reviewed quotation with the nameplate photograph and drawing.
Frequently asked questions
Who makes replacement pumps for the Goulds 3196?
ITT Goulds makes the 3196 itself. Non-OEM manufacturers whose own pages describe a pump built to the 3196 dimensional pattern include Dynapro (D-196), Sunbo (G series), Curflo (G-Line) and YSM Pumps (G196). Other makers’ ANSI process pumps, such as the Summit 2196, PumpWorks PWA Gen2 and Peerless 8196, are listed above with what their own pages and literature publish. Interchange for any of these pumps is confirmed against the installed pump’s nameplate and drawing before order.
Can a non-OEM pump built to the Goulds 3196 dimensional pattern be installed without checks?
No. A pump of the same ASME B73.1 designation and frame group is built to the same baseplate, nozzle and shaft envelope, confirmed against the nameplate and installed pump drawing, but hydraulics, seal-chamber geometry, materials, rotation, auxiliary connections and internal parts are the manufacturer’s own. Verify nameplate, GA drawing, curve, seal arrangement and coupling before treating it as a like-for-like fit.
Does ASME B73.1 make every ANSI pump interchangeable with a Goulds 3196?
No. B73.1 aligns mounting dimensions, nozzle size and location, input shaft, baseplate and foundation bolt holes for pumps of the same designation, but it does not standardise performance, impellers, casings, seal-chamber geometry beyond the minimum envelope or materials. Interchange for a specific pump is confirmed against its nameplate and the installed pump drawing before order. The interface-by-interface reading for the 3196 pattern is on G196 vs Goulds 3196 interchangeability.
Should I buy a complete pump, a bare wet end or parts?
It depends on what is installed. A complete pump suits a worn power end, a changed duty or a plant that wants a new nameplate and full documentation. A bare wet end on a sound existing frame covers casing, impeller, cover and adapter. Parts suit a sound pump with individual worn components. For any non-OEM wet end or part, the OEM warranty terms are checked first and fit is confirmed against the nameplate and the installed pump drawing before order.
What documents should a replacement pump come with?
A certified general-arrangement drawing, a sectional drawing with parts list, the performance curve for the offered impeller trim, material certificates with heat numbers, hydrostatic, balance and dimensional inspection reports, and a performance-test report or third-party inspection report where ordered. Check these against the nameplate, model, serial number and purchase order on receipt.
Is a Durco Mark 3 interchangeable with a Goulds 3196?
Only at the ASME B73.1 mounting and nozzle envelope for the same designation, and that is confirmed against the nameplate and the installed pump drawing before order. Casings, impellers and covers are specific to each pump design. For a Mark 3, see YSM D Mark III vs Durco Mark 3; the D Mark III is built to the Durco Mark 3 dimensional pattern under ASME B73.1, same size and group, confirmed against the nameplate and the installed pump drawing before order. Durco and Mark 3 are trademarks of Flowserve.
Confirm Interchange for Your Installed Pump
Send the pump nameplate, the installed pump drawing and your duty data. The size, frame and configuration are confirmed against them before order.
Trademarks and non-affiliation
All manufacturer names, model numbers and trademarks are used for reference and compatibility identification only. YSM Pumps (Jinan Yingsiman Machinery Co., Ltd.) is not affiliated with, sponsored by or endorsed by any of these manufacturers, and is not a distributor for any of them. All pumps and parts are non-OEM and manufactured by YSM. Interchangeability refers to dimensional interchangeability of the referenced standard designs; verify size, group and configuration against the pump nameplate and the installed pump drawing before ordering. Goulds, 3196, i-FRAME and ITT are trademarks of ITT Inc.; Dynapro, Sunbo, Curflo, Summit, Peerless, PumpWorks, Griswold, Durco, Mark 3, Flowserve, SKF, John Crane and their model names are trademarks of their respective owners; none of them has reviewed or endorsed this page. OEM model names are used only to identify the dimensional pattern.